You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
You are viewing the article in preview mode. It is not live at the moment.
Home > TAS / TAS-A Dealer Support > Skytrax 6xx; TAS-A (Dealer) > Release 9 to TAS-A interface with release 9.4
Release 9 to TAS-A interface with release 9.4
print icon

Release 9 to TAS-A interface with release 9.4

 

https://desk.zoho.com/DocsDisplay?zgId=58375072&mode=inline&blockId=9xd2y53d549f9acee40c9beaa4f55f920cf5bConfig Tool Selection for TAS-A

R9 IFD Control and Display Wiring to TAS-A:

  • TAS-A RS422 - In: J121-24 (Port4 of 0-5, actually the 3rd RS422 port if you're separating the 4 RS422 ports from the 2 RS232 ports 0-1)
  • TAS-A RS422 - Out: J121-66 (Port4 of 0-5)

R9 IFD GPS output to TAS-A:

 

TAS-A A429 - Out: J121-15,36 (Port4 - Arinc743 labels - the wiring also goes to TWX although the TWX ignores with A743 labels with no ill effects)

 