Entegra EXP5000 PFD Part Number
-
Cirrus PFD Lightning Protection Diodes
When these diodes go bad, the indication is typically a "PFD Not Communicating" message on the MFD, and loss of engine data on the PFD, assuming both are properly configured.
-
Entegra EXP5000 PFD AutoPilot configuration Cirrus
This is informational use only, all inquiries regarding the Auto Pilot issue below must be referred to Cirrus. Issue: shop is able to save Auto Pilot as "Not Installed". Workaround: None, this is required by Cirrus NOTES: Cirrus requires the PFD validate the configuration options, and only allow the options tha…
-
Entegra EX5000 PFD or MFD Connectors
When reinstalling the PFD or the MFD, refer to the aircraft installation guides for the pin connectors. Assuming the connectors on a replaced or repaired unit are incorrect, will delay your re-installation of the unit and delivery back to the pilot. For example, Connector J731 is on the back side of the PFD in thi…
-
DFC90/100 Servo Start Up Voltages - Cirrus and Piper
This should be tested using a variable DC power supply, connected as displayed in the image below: Once connected, begin at 0VDC and slowly increase voltage until the servo begins to respond. That will be your "start-up voltage." DFC90 Servo Start Up Voltages Roll Servo should be less than 3VDC Pitch Servo…