MFD getting Engine Sensor Not Communicating and ALL data blocks on the Engine Page is dashed-out (example photo's below) - verify power and ground to the SIU/DAU - If SIU/DAU is good - Contact Radiant Power Radiant Power (DAU & SIU) Repairs 7135 16th St E #101, Sarasota, FL 34243 (941) 739-3200 email contact…
Aircraft installed with an SIU (Sensor Interface Unit) should not have an engine data block on the PFD. If you see the Engine Data Block and it is dashed out the PFD is configured incorrectly. An avionics shop will be needed to update the configuration of the PFD. 1) Hold down L1 and L3 to enter into In M…