On the Synchro Valid input R1 and R2 must be installed or the EX500/600 will sustain damage. If the unit is receiving HDG data, but the HDG is jumping all over the place check: 400Hz output of the A/C supply Check reference Hi and Low compared to X,Y,Z inputs. The reference and signal input wave-forms must be iden…
All EX600 MFD's have the same base part number of 700-00167-xxx. It is these last three digits that determine which variant it is. -001 = EX600 Black Bezel; No Radar interface -002 = EX600 Black Bezel; RDR 1100/1200 -003 = EX600 Black Bezel; RDR 1300 -004 = EX600 Black Bezel; RDR 130/150/160 -005 …
These units are now repaired/supported by Duncan Aviation. To remove the EX500/600, you will need: Avionics standard 3/32 allen wrench. FSD, ATD150, MHD300, EX500 and EX600 product lines, D98-00001-58B, 1/2 3 ATI Duncan Technical Support •Normal Business Hours Ph: 800-562-6377 (Int’l 402-475-2611/ Avionics Repair…
For EX600 & EX500 MFD-equipped aircraft: •For ADS-B OUT -Avidyne offers IFD4XX/IFD5XX FMS/GPS navigators for approved GPS position source -AXP340 Panel-mounted or AXP322 Remote-mounted Mode S Transponder -Info below is related to the 4.2 series software; refer to the applicable Install Manual for compatibility an…