_**IFD5XX/4XX AT 10.2.X or Higher**_ For IFD5XX/4XX currently at S/W Version 10.2.X or higher you can obtain the GPS Rollover Software at: **https://dealers.avidyne.com/files/downloads/500-00274-000_GPS_PATCH.dsf ** Additionally, you can obtain the Service Bulletin for this upgrade at: **https://dealers.avidyne.co...
EXP5000 - GPS Navigation Integration Test **Vertical Deviation Indicator (Item 14) is not displayed on the EXP5000 PFD when completing checks Instrument Panel Self-Test with a NON-WAAS GPS.** ![https://techsupport.avidyne.com/support/ImageDisplay?downloadType=uploadedFi le&fileName=VDI2.PNG&blockId=4aad1310905b20a...
The IFD is providing all of the deviation data to the Aspen via ARINC 429 (digital) and the Aspen then sends that digital data to the ACU, which processes the information and outputs the analog equivalent to the autopilot. The way the Aspen does this is dependent upon what mode is selected on the Aspen. For instan...
All Avidyne R9 units should have been updated to 9.3.3 (mandatory update in 2015). If you are troubleshooting an R9 with the software version below 9.3.3, you must work with an Avidyne Dealer to have the GPS and ACR blades, from both units sent in, for the 9.4 update. Shops attempting to update the R9 system from an ...